Variable

UK Data Service variable record for:

English House Condition Survey, 2004

Variable Details

Variableffrsncc
LabelReasons for decision not being clear cut
Responses
1. Disrepair - electrics appear unsafe & dangerous. 2. Ventilation no window only door to living room. 3. No light switch at top of stairs but exists to landing. 1
9999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999 9
? 1
Access not possible for adequate inspection erred on side of borderline fit but a second surveyor may have judged unfit. 1
According to the owner the drains to the rear garden block up & overflow intermittently. Another surveyor may think this sufficient to cause unfitness. 1
Although cooking location is adjacent to door leading to external - door does not actually strike cooker & door does seperate user from cooker - thius hazard is reduced 1
Am not happy with ventilation to kitchen/dining area - install mech. extractor fan to kitchen/diner. 1
An accumulation of defects are evident but not one by itself serious enough to warrant unfitness. 1
At the time of survey the module was undergoing a complete reroofing the structure was in place but a majority of the tiles were not present. The module was protected by a temporary roof , work in progress 1
Back addition roof - may not be ongoing. Penetrating damp - works in progress. Disrepair - insufficient items to class as unfit. 1
Basket of necessary repairs is substantial with damp in living room, dining room and kitchen. Rising on internal walls only. Exacerbated by condensation. Ground floors settling today but tennant reports much worse in winter and "it stinks" but was 1
Bathroom has condensation dampness with associated mould growth,on balance not pervasive enough to render unfit. 1
Bbay belling situated on drop down worktop, not sure if could be easily remedied to take out portion of worktop & cupboard to fit cooker, or if necessary in a one bedroom flat/sheltered housing! 1
Borderline decision as to whether w/c location, which is in the bathroom but sited directly off the kitchen, makes property unfit. Decided that hands can easily be washed in w.h.b. and that this defect does not make house unfit to live in 1
Borderline fit - defects to above and below ground drainage systems. A second surveyor may have judged unfit. 1
Both bath and EHB still useable and so could have been classed as defective 1
Both in disrepair and needs renewal, however , is usable and in use. Disrepair will hinder cleaning. Seems a little harsh to fail house on this one item alone. 1
Collective disrepair to all areas through neglect & bad diy not immediate prejudical to health but needs corrective action in next 2-3 years. 1
Considerable rubbish & disrepair to paving,fence missing,slabs removed as a result of building works in progress & will be short term only. 1
Considered immediate harm as broken consumer vent cover has exposed live conductors - risk to health but relatively straight forward remedy - renew cover. 1
Could have gone either way on both counts!! Repair, main item is no or failed DPC to kitchen causing RD with other disrepair to pointing and stocks. Borderline, however effect of the defect is rising damp which impacts on health. The RD is in the 1
Could not determine if gas appliance was more than 7.5 kw so unfit decision is based on an assumption that it is class one gas appliance. 1
Dampness appears to be at low level and plaster not yet greatly affected (twice chemically injected!) Full extent not known. 1
Dampness caused by condensation is affecting all habitable rooms, kitchen & bathroom. Mould growth on external surfaces and to majority of ceiling & bathroom. Levels of mould growth to kitchen, bedroom & living room small; mostly down in comes under 1
Dampness in kitchen, though limited by almost full tiling. Dampness to living room walls. Partial ceiling failure to kitchen taped up & to bathroom (less significant). Local spring in circulation floor. CONTINUED IN EXTRA NOTE 1
Dampness noted to no. of grd flr and 1st flr rooms. Grd flr assume no effective dpc. Whilst grd flr walls felt cold/damp not much visible evid. of damp/mould growth. Very borderline.Provis of ctrl htg poss masked prob. Vis evid stronger to 1st flr rm 1
Decided after further review that is not unfit, just defective as even cumulatively they do not make a property unreasonable or unsafe to live in 1
Decided defective mainly due to missing balustrade - could be considered unfit as potentially dangerous but I dont think so as it is easily remedied. 1
Defective as only access to bathroom is currently via a bedroom. This is due to be changed once renovations completed. There is an alternative WC & WHB available on ground floor. 1
Defective clear cut on cooker location by kitchen extension door, but Defective not clear cut on damp rising in 4 isolated points in living room - could therefore be unfit in but not in my opinion 1
Defective due to lack of hot water. Repair to hopefully be made in few days time. At survey time had no hot water for 10 days. Lack of hot water is prejudicial to health due to difficulty in cleansing body. Also risk to health in food preparation 1
Defective mainly due to interior fabric condtion 1
Defective on size of kitchen -oven door will not fully open-because of fridge/freezer.Draw also blocked by oven-but a small fridge may be more reasonable for this size of flat & would mitigate the problem. 1
Defective only due to lack of heating on 1st floor including bathroom and all other rooms except lounge/diner. 1
Defective roof covering (concrete tile) to whole block only issue to class property as defective 1
Detached brick built outbuilding showing signs of structural instability. Close proximity to rear addition poses a risk (slight?) to occupants/users of house. Borderline decision. 1
Disrepair to envelope of building due to lack of maintenance but borderline as to how affects survey flat. 1
Do not know extent to corrision of frame. Rear wall seems most affected, currently not unfit but needs investigation. 1
Door in kitchen opens onto cooker area. Large enough kitchen that could be rearranged. Cooker could be built in elsewhere. Would need builder. 1
Extensive disrepair to exterior, whole gable needs repointing. roof repairs - bulge at base of gable apex needs tying, windows on rear need attention. Bath badly worn enamel on cast iron bath. However: impact on health & safety does not make unfit. 1
Extent of rising dampness not clear (eg most of kitchen is dry lined and single brick construction) 1
External disrepair at defective level nut only just and not affecting fitness internally. also repairs are ongoing. 1
Felt that extent of disrepair high-borderline fit 1
Food Prep: Very small kitchen, however good use of space and in good condition. Not a through route o risk from hot surfaces minimised. Applying whole - house standard would make an unfitness judgement harsh. 1
Hazardous kitchen layout with kitchen adjacent to doorway - however hazard not extreme. Door does not strike cooker or user. 1
High external level nearly to DPC adjacent to rainwater down pipe and gully. (Internally adjacent to duct containing soil stack). Difficult to ascertain whether rising damp or penetrating damp. ..........cont. in paperclip note 1
Home is being totally refurbished to a good standard. There are other bathrooms in the home. 1
House has had new roof flashings etc & DPC is well heated & good bathroom & kitchen, fully rewired & plumbed. However boxroom lit only by one small high rooflight - has to be used because of family size but vent just OK as through vent off landing 1
I consider the kitchen to be of inadequate size to provide the necessary amenities-cupboards,worktops & cooker .others might come to a different conclusion no cooker point 1
Ill fitting doors, windows defective, but not many and an easy repair 1
In process of being refurbished, including repairs and heating system prior to being re let. 1
Inadequate permanent ventilation to heat producing appliance (BBU) as a result of new unventilated sealed external front door (Supervisor informed) 1
Isolated lintel failure,only reason for defective judgement. 1
KITCHEN IS ONLY BARE MINIMUM TO FITNESS STANDARD. EXTENSIVE DISPRPAIR INSIDE TO PLASTERING, ELECTRICS, ETC, BUT IS SATISFACTORY TO EXTERIOR 1
KITCHEN WORKSURFACES MISSING - BUT TABLE PROVIDED AND KITCHEN IS VERY LARGE OR WORKSURFACES COULD EASILY BE INSTALLED - WASHBASIN TO BATHROOM CRACKED BUT ALTERNATIVE WASHBASINS PROVIDED IN BEDROOMS. STAIRS NEED HANDRAIL - COULD EASILY BE PROVIDE 1
Kitchen door into kitchen opens inwards onto part of cooker - large range, two thirds outside door swing - but door has vision panels (though small children pay little heed - therefore questionable unfit. 1
Kitchen floor (cupboard got wet). Possibly long term leak. Floor structure lost integrity & become spongy & several holes in altro floor covering - survey been carried out & floor to be replaced under household insurance. 1
Kitchen has no worktop as it is and no space for one to be provided easily (or table) without carrying out work. 1
Kitchen units and worktops in poor condition require replacing but not quite unfit. These will be replaced this year by Bradford Housing Trust. 1
Kitchen very small and not enough space for 1m mr of work surface. Also cooker position relative to work: space is a hazard. Flat is one bedroom and for max 2 people, so not considered to be unfit on this basis. 1
Kitchen. Enclosed by double glazed conservatory. However, no solid door between kitchen and dining area - whiche is adequately ventilated. Mech extract fan necessary (not easy) to kitchen 1
Living room with gas fire has no ventilation. No grill vents on own birch. Conservatory to back 1
Lots of minor problems of disrepair & extreme untidiness which makes assesment difficult. 1
Majority of fitness items clear cut,but not clear cut on dampness.(Due to condensation),as it would depend on time of year surveying .Likely to be unfit during the colder months.(eg. winter period). 1
NB Utility built from stone slab walling (approx 2") of the rear yard party wall and timber panel - very poor construction 1
Naf ventilation- kitchen/diner- openablewindow area only 1/32 of floor area.(no extractor fan) main bedroom 1/39 of floor area. Other two bedrooms slightly under 1/20 not causing any obvious problems 1
No balustrade to stairs and no handrail on wall but easily installed by a DIY handyman. 1
No hot water to bathroom is only reason for unfitness. This is only means of washing the body - no shower facilities. Has been like this for several years. May be simple repair necessary. 1
No hot water to wash hand basin - only one wash hand basin. Some may say flat unfit as cannot cleanse hands sufficiently 1
Number of items of disrepair, none of them serious in their own right, but collectively close to making dwelling unfit. Dampness present but considered borderline fit. 1
OCCUPIER SAID PROBLEM WITH FLOODED DRAINS BNUT NO EVIDENCE VISIBLE 1
Obvious cracking to front & right flank wall. Telltales indicate council investigating settlement crack's but tenants not been informed of reasons. 1
Occupant advises of frequent & recurring blockages to drainage system affecting rear of property (sink waste & garden). A trap has been cut into the timber floor of the kitchen to allow access to the system to aid clearance. However, there was no 1
Old Belfast sink with no drainer but tenants choice. 1
Old property with neglected maintenance most of disrepair exteriot which eventually will impact onto living conditions 1
Only defective in communal areas. Individual unit would have been acceptable. 1
Only one bedroom with damp penetration in corner (flat roof/soil pipe over) affecting 15% of ceiling 10% of wall. May be simple repair job. Heavy rain at time of survey but damp not very severe, could also move bed into living room 1
Original kitchen in place. Work surface completely broken up & unhygenic. Borderline unfit. 1
Patio windows only to living room-condensation problem-also in bedroom 1
Please see attached notes. 3
Please see note attached 2
Please see note. 1
Please see notes 4
Please see notes attached 1
Please see notes attached. 1
Please see notes. 2
Position of cooker is dangerous but would not be v diff to resite - needs gas point resiting. Basket of disrepair items includes in particular bulged and holed plaster to a partition wall in both upstairs bedrooms. 1
Postion of cooker next to door. Layout could be re-arranged to accomodate better position for cooker (without too much alteration). 1
Problem with condensation dampness in number of area caused by installation og D.G.windows/insulation etc. This has led to cold-bridges because of dwelling design/age. Rooms affected not main livivg room but occurs in rear LR becuase sub-floor 1
Property is only defective due to insufficient heating on 1st floor level & rear dining/kitchen area. 1
Property only fails on a technicality. Whilst WHB is provided, it is not close to W.C. Other than this this property is generally okay. Seems a bit harsh to fail property on this point alone, however, W.C. is closer to the kitchen than the WHB. 1
RWGS-some sag and poor layout-no signs of leaks and dry at time.Dampness-ground level-no signs of damp internally but recently redecorated! 1
SEE NOTE. 1
SEVERE PENETRATING DAMP CAUSED BY LEAKING STONE GUTTER. OCCUPIER STATES PROBLEM NOW RESOLVED, BUT STILL VERY DAMP IN AREAS ON DAY OF VISIT. 1
See attached note 1
See attatched note. 2
See note 14
Seems to have stopped moving but has been painted over recently. 1
Serious condensation on windows and gable wall. Level of use of heating/ventilation not clear 1
Shower is designed for disabled access from wheel chair but very small as described below with no changing area, is directly off main room - but purpose built sheltered home 1
Significant mould/condensation affecting all top floor rooms,worse in bathroom,not considered seriously defective but border line decision likely to be considerably worse during winter months. 1
Slight damp to external and party walls in bathroom. 1
Slopping floors to 1st floor, overall amounts of disrepair eg cracked plaster to internal walls, and to the rear elevation render. Maybe unfit due to lack of sufficient heating eg no insulation, 2 room gas heaters only. (back lounge and dining room 1
Some substantial defects noted, but on the whole these are localised. Any further deterioration would be likely to merit an overall judgement of unfitness. 1
Subjective decision on cooker location. No adjacent worktops and close to back door. 1
THERE IS ALOT OF DISREPAIR-WINDOWS,WALLS,ROOF,GARDEN,CHIMNEY,GUTTERS,FASCIAS,BUT ALL OF IT IS EXTERNAL AND DOES NOT POSE RISK TO THE OCCUPANTS.K 1
That property coming to end of refurbishment which involved areas of replastering , floor repairs. Bath/WC/WHB stripped out stored in other rooms for refitting. So not immediatley suitable for occupation, but refitting of amenities, (continued) . . . 1
The area behind first floor toilet is not capable of being cleaned, but could be made good without major works or expense. There are holes in the bathroom door. Door needs replacing only. 1
The bath has got sighnificant scratches and is just about cleanable but is close to becoming uncleanable, and will need replacing soon 1
The bath has previously been resurfaced twice. The coating has failed badly and the bath cannot be properly cleaned. 1
The house is in very good condition apart from inability to clean behind toilet . Minor work could cure this defect. 1
The kitchen has a 30 amp provision for a cooker but occupier does not have cooker due to space limitations in kitchen - instead she has got a washing machine & tumble dryer & uses a small 'one ring' type cooker on worksurface along with steamer! 1
There is hot water supply from the back boiler to a cylinder but no immersion. Therefore, have to have fire on to get hot water. Coded as a minor repair pm hot water to sink, bath, wash basin = total adds up to fitting an immersion heater 1
There is ingress of rainwater to the ceiling of both the top floor bedroom and the living area below it, presumably caused by a problem with the flat roof. The ingress is not serious as yet and is not enough to make the property unfit although 1
There is no WHB or intention to install inmain bathroom/wc , however, there is a whb in gound wc cloakroom 1
There is no ventilation to lounge. This is part of the work to be carried out to complete the building. 1
There is some movement in the house - don't know extent or if ongoing but I think so. Monitoring needed or someone who knows more about this than me! 1
There were a number of disrepair items,but due ti the size of the hiouse none caused too much inconvenience to the users. eg. the main bathroom was defective but there were 2 good ensuites and another wc. 1
Three grounds where believe defective clear cut. But in respect of food preparation - not cooker is situated immediately adjacent to outside door and entry/exit would interfere with user of cooker. As external door and limited use believe not unfit. 1
Unfitness decision rests on dampness. Mould/condensation pervasive to bathroom,but not damp at time of visit. Additional damp to kitchen. Possible that condensation to bathroom occurred during previous occupancy/lack of use of heating. 1
Ventilataion - high level skylight only to kitchen. Tenant never opened as unaware of how to close again to prevent eg increase of rain. (Maybe a very long stick will suffice??) Mechanical extract fan required. ess of rain. Mechanical extract an 1
Ventilation - only bathroom has no natural or mechanical ventilation. Has window but totally enclosed by rear hallway. Not particularly easy to provide mechanical ventailation - will need ducting. 1
Ventilation-window to bathroom obstructed due to utility room being built to side of property.Bathroom now vents into utility room-evidence of condensation. 1
Ventiliation to living room - small window for volume of room - (kitchen/living/dining area combined. L shaped room. Extract ventilation for kitchen, but without this window, is really very small for this habitable area. 1
Very borderline - generally in a poor state with a couple of structural problems, horrible staircase and poorly lit ventilated living room - but: it is comfortably occupied, dry and warm. 1
WHB is in 2nd bedroom (next to bathroom) 1
Well,the occupier (the man in the street) clearly did not think that totally enclosing a small kitchen would render their house unsuitable for human habitation.Diff install extractor system. 1
Whilst roof not leaking. Many slates have slipped & been temp refixed. Owner applied for a grant but wont be eligible for three(3) years. Will therefore have to wait to replace roof. 1
Whole of bathroom ceiling is mouldy - but rest of room ok/rest of dwelling acceptable. 1
With some work windows could be freed (windows painted over). 1
Would require survey whilst raining to ascertain causes of dampness. 1
a bedroom without available ventilation is unsuitable and is causing damp /condensation and mould growth, but is easily remedied by removing or altering the secondary glazing 1
a number of problems; no w.h.b. by w/c inadequate kitchen storage, some cracking evidence of slight movement in bathroom. Individually im not sure these problems make the property unfit. 1
age of property combination of external and internal disrepair, structural - roof sagging, dampness to bathroom(condensation) combined factors - property could be unfit 1
all defective items are because of ongoing refurbishment 1
all opening casements to all groung floor rooms have been nailed or screwed shut as a security measure. whilst this may not be a huge task in rectifying deflect (may be easier to some windows than others) the fact of having PLEASE SEE CLIP NOTE 1
alot of disrepair to all areas internal and external and fitness on heating is marginal 1
bath requires replacement as not cleanable but may not be poor enough to ? unfit 1
bathroom access via bed 2. only wc in bathroom 1
bathroom extractor fan may not be working-difficult to adequately assess-may be a contributory factor for condensation elsewhere in flat. 1
block is due for demolision lots of vandalism and vacant flat with no heating causing condensation and black mould to all windows, serious disrepair although actual flat not unfit 1
border line unfit due to disrepair. 1
borderline acceptable - fabric repair will be easily dealt with during redecoration now in progress. dampness cured by extract vent to kitchen and insulation to flat roof 1
borderline defective due to inadequate food preperation provision and minor external disrepair 1
borderline unfitness numerous areas of penetrating dampness although possibly exagerated by tenants inability to open windows h/assos is due to reclad property in near future 1
build up of various repairs needed and not defective for one particular item and most repairs external 1
conservatories/block light and ventilation to bedrooms 1
considerable disrepair but probaly not sufficient to say it is unreasonable to occupy.also problems to w/top & kitchen units affect cleanability. 1
cooker in dangerous position but the council are planning to block up doorway to rectify problem 1
cooker located imm adjacent to rear door access.This the only major fault found(with the exception of the disrepair to the attached garage) cooker loaction could be classed as dangerous, house generally fit. harsh to fail house on this one item 1
cooker postiion bad - possibly could be easily moved 1
corner bath newly installed in bathroom leaves very small space to enter bathroom.If a normal sized bath was reinstated the problem would be solved 1
cracks to left hand side elevation. Recently caused, needs further monitoring 1
damp penetration may be condensation 1
dampness disrepair and food preperation re marginal 1
dampness kitchen due to high ground level of 1 metre above floor level - remedy descrived elsewhere, borderling fit not affecting key habitable room 1
debatable whether extent of defective plasterwork makes it unfit new tenants are re - decorating throughout and have not reached defective rooms plastering repairs needed in kitchen and bathroom 1
decision on FOOD PREP WC AT DISREPAIR are all marginal, but position of cooker is dangerous. At combined faults probably unfit disrepair but individually within fitness standard. 1
defective area is to common areas damp repair plaster overflow waste pipe at external wall 1
defective by virtue of rain water goods to both elevations hanning off/blocked but no effect on internal space 1
defective due to disrepair-main develt is blocked rear gutter to main house, causing overflowing into rear yard and into gable wall and pavement. ugently repair needed, but not yet affecting the rear of the property. otherwise acceptable 1
defective due to inadequate vooker space,cracked wash basin in bottom and unventilates wc following construction of porch extension.not considered unfit on any simple ground but could be unfit in aggegate 1
defective kitchen layout could be remedied by moving cooking facilities or providing alternative cooking facilities 1
defective mostly due to disrepair in Kitchen & services some of these are presently being upgraded as new owner only been present for 2 wks 1
defective on fabric repair but the occupants are in the middle of refurbishment/redec,re-wiring just completed etc-could be acceptable 1
defestive due to need to repair slipped slates on rear roof plane only 1
despite obvious problems,efforts of occupants wieh dehumidifiers and constant heating ae able to keep the place habitable 1
difficult to access facilities but not totally impossible could be worse but not much 1
disrepair is result of ongoing diy upgrade nightmare. inpact on occupants is remarkably small but it would be less fit for small children/elderly people 1
disrepair relates to no.minor problems.Means of escape is dangerous due to condition of torn carpet and attificial light in disrepair. 1
disrepair to windows not sufficient to make them unopenable,stll provide protection from elements+safe.kitchen cupboards in poor repair-but many can still be used.disrepair to walls not affecting h&s of occ to extent of masonary unfit 1
dk 1
doors removed for cinvenience-only mould noted in small area - open windows would eleviate. Vertical cracks in some intr walls noted 1
drainage defect physically affects only ground floor maisonette in module-subject dwelling is first floor maisonette, with its condition being otherwise acceptable. 1
drainage to septic tank is faulty causing seepage around the tank as the tank i s in an adjacent field the house itself is unaffected, facilities is use without detriment within curtailage 1
drainage-gutters broken/blocked,surface water drain overflow. repair-hole in roof,floor boards broken. but weather is affecting the use of house and occupants are busy refurbishing. 1
drains prone to recurrent blackage. not blocked at time of survey . no investagrative work has been undertaken to ascertain reason only reactive response. 1
dwelling lacking worksurface of adequate depth-existing work surface is 40cm wide.there is also a pull out table which can be used to provide a small area of work surface,adequate worksurface could be installed. 1
electric very old and nor rewired since tenant moved in 33 years ago roof sagging and covering requires overhand (looks original) and causing penetrating dampness to bedroom 1
electrical installation cannot bee safely reconnected without major repair of consumer units and some fittings 1
electrics - 1960's switch fuses, inadequate earthing, some old lighting switches - assumed rewire & possible health & safety risk - but not definite risk. 1
evident of severe settlement in area. some houses demolished/chalk mining# 1
extensive building rubble/ materials around front shared access could make the property unfit,but problem is temporary and easily cleared up. 1
extensive disrepair throughout - borderline decision on fitness 1
extent of dampness and mould, problem cant be assesed untill winter 1
external drains keep blocking 1
food prep-there are two worksurfaces only one in poor repair.cupboards are poor but will not be unhygenic or hazardous.Disrepair-mainly windows. most can be opened with difficulty but do not yet give rise to serious inconvenience or predjudice h&s 1
food prep-very small kitchen currently being refurbished. condition expected to be resolved in short term;however still minimal space and only available cooker position potentially hazardous 1
food preparation, believe not unfit. no dedic 1
further investigations needed as to exact cause/causes of condensation .lifestyle related or lack of background ventilation.Heating is from storage heaters supplemented by single panel on?peak electric heater - no trickle? vents s 1
ground floor wc. no wash basin and insuuficient room to fit w/b in compartment. indequate room to fit wc in bathroom. without relocation. nearest handwashing facilities to wc is adjacent kitchen. 1
history of blockeddrains causing flooding to ground floor w/c,though not at time of survey 1
hole in roof-10 tiles dislodged by wind-no water in-council repairers due-decision marginal 1
in respect of food preperation and dampness the dwelling is close to unfitness.there is also comparative minor disrepair 1
intermittent blocking of underground drains 1
internal plaster-kitchen area not affected. 1
it is not clear whether settlement is still taking place.if it is then the property is clearly unfit and the works carried out were insufficient. 1
kitchen 1800mm widw with inward opening door obstucting space in front of cooker-very tight for new house 1
kitchen borderline,very old units just adequate for storage for l occupant worktops ok , space limited but just about adequate, quite a lot of disrepair but not too serious 1
kitchen cupboards doors & drawers poor & illfitting but usable&clean-no health or hygene issues.worksurface-an area is in poor surface repair-severe-but other areas are ok& cleanable-not severe or extensive enough to make unfit 1
kitchen cupboards in poor repair but not unusable or unhygenic so not unfit.Worksurface required sealant renewing only quick & easy repair,so not unfit.repair to some all surfaces needed but not so bad to make seriously defective 1
kitchen generally useable and occucupant coping all be it with very inadequate work top provision of total length of cuboard units for food storage local authority need to take urgent action on these properties occupant living l950 standard kitchen 1
kitchen is defective on food prep because belfast sink has no drainer or space for drainer.However,the kitchen(15years since refurbished-incl sink)is in very good condition and the rest of house is in otherwise satisfactory condition. 1
kitchen layout with position of gas cooker near back door and oppersite the dining room and back of work surface makes it borderline for fitness 1
kitchen pretty small for a 3 bed home.just about acceptable until a fridge freezer is neede , then no space for one. 1
kitchen totally enclosed by dg conservervatory,no ventilation to outside air which is a fitness requirement. not clear cut as many be considered that easily rememed by installing mechanical extract fan with ducting.not easy 1
kitchen windowopening too small,in effective ventilation.serious condensation in kitchen. 1
lack of drainer /second bowl to the sink is only reason, I consider this to be a technical failure .On its own not sure this is sufficient to fail the whole house as unfit and not reasonably suitable for occupation 1
lead pipes still in parts of property. lead levels in water unknown-cannot say if water fits or not 1
level of disrepair not sufficient to be clear cut 1
living room had sliding patio window-not practical to ventilate room in adverse conditions/security reasons.Have specified change of windows. Becoming increasingly common and altho a fitness issue, an awful lot of properties would be unfit .ws ONLY. 1
location of wc on ground floor off hall no whb,however thereis a whb on the same floor as bathroom seperated from wc by kitchen 1
main item is heating system-but hot water ok and can use portable appliances 1
main living room comprisers of front and back rooms made into one/kitchen extension has been added the rear of building licience natural ventillation to living area natural lighting also affected. some doubt as to wheither this is sufficient to 1
main livingroom tottally einclosed by dg conservatory ie; no ventilation direct to outside air. not clear cut as this arrangement seems tobe accepted by many 1
main problem dampness,could be high occupation(7occupants) window kept shut etc. drainage-concern on concrete gutter system but cannot inspect inner surface 1
majority of dampness located in first floor front bedroom. only small patches of dampness throughout the rest of house. two alternative bedrooms washable 1
minor items of disrepair and major dis 1
nat. ventilation-approx 1/30 to main living-but has a front door opening into it.dining room has a door onlyand one bedroom appears deficient in natural ventilation. 1
no 30amp cooker point only baby belling on 13amp plug.Room for cooker point and full size cooker. 1
no provision for cooker and worktops 500mm 1
no ventilation to kitchen area is only grounds for unfitness; otherwise would be defective 1
not clear if not functioning roof draining in this instance is having significant effect onthe whole house-no signs of problems inside resulting 1
not sure of extent of dampness. both bedrooms and bathroom ok dampness in diner and all along hall wall only 1
not sure whether treatment has cured defect. signs of damo in gf bedroom-occupier says it has recently been treated-may be dry rot. 1
nsure of the extent of corrosion in frame. Kitchen layout - cooker next todoor-possibly coild be moved slightly to reduce risk 1
number of items of disrepair, none serious disrepair in their own right. consedered borderline unfit 1
occupant informed me drains /sewers keep blocking due to way they were initially laid falls and bends leading to blockage dont have enough information to say whether clear cut or not 1
occupation of the flat is contributing to the dampness rather than strictly the flat itself being in disrepair/having poor vent. however it is a very cold flat. 1
occupier in process of fitting whb in gf toilet - but not yet functioning 1
occupier state wiring not rememed since they moved there 48years ago. some evidence of lectrical installation being checked over. light switches and sockets renewed but some original lighting pendants.. 1
only problem was proximity of rear door to site of cooker.dangerous but felt not enough to declare unfit-possible to resite 1
only small patch of burnt worktop 1
only wc off kitchen on g.f - no whb near wc - the whb is on ff in bathroom 1
only wc on ground floor accessed from hallway.hwb at first floor level and household likely to use kitchen,sink located very near wc. 1
openable window area-natural ventilation to main(and 0nly) living room appears to be only 1/34 offloor area.This is well below 1/20,tho I believe that some would not deem the flat unfit on this one count-also,entrance door can provide some nat venti 1
patches of damp through out the property. two ofthe first floor rooms not used and this may explain some of the damp(condensation/closed spaces). damp not extensive but lots of isolated patches 1
penetrating damp caused by leaking gutter from adjointing property.border line fit 1
perished wall plaster,slipped & missing slates,rotted sills,dpc bridged,reverse falls etc. tiles removed in bathroom(v.temporary)no outer banister or balustrade on stairs. 1
plaster missing, cracked and perished in most rooms. bedroom doors missing 1
position of cooker adj. door to kitchen is dangerous-with one person living at home this is not as dangerous as a family with children 1
property had a no. of relatively serious problems but 1
property has disrepair in all areas, no clear cut decision on unfitness 1
property has high level of disrepair 1
property has whb in gf bathroom,although wc is on first floor.fairly good prospect that whb would be used and not sink after using wc 1
property immaculate kitchen has a door open to outside air.never the less 3 main rooms have no natural ventilation direct to outside airby window means 1
property is generally in an acceptable condition but the units and cupboards in the kitchen are verylimited and dated and need to be replaced. 1
quite alot of disrepair particularly to interior of dwelling.none of disrepair serious in its own right and collectively considered to be just fit on disrepair grounds.border line decision 1
rear roof has a slight sag to it. There is small pockets of damp/ due to ineffective damp proof course. 1
recurring septic tank blockages and mal function. when water table is high. dwelling could be degmed (no easy remedy) to be defective or acceptable 1
refurnbishment due in the next 3 months,assumed to include roof,windows-not seriously affecting occupants 1
relatively modern (1970's) abd well maintained house but has missing guarding handrail to stairs. part is protected by a wall but still unprotected drop up to 1.5m 1
relatively united mould growth in bathroom - but very exposed 41/2" wall (high heat loss) could give severe conditions in winter but does have radiator and extractor. Possible bridged DPC. 1
repair to kitchen cupboards &work surface did not make kitchen unusavle or unhygenic to point of unfitness.Disrepair to windows&fabric not urgent.windows can still be opened and fabric disrepair not severe enough to make unfit 1
rising and penertrating damp to kitchen not quite severe enough to make unfit 1
rising damp to both grd floor rooms & dry rot in skirting not causing discomfort could easily score 2 N buit score 1N on disrepair - just! could be 2N on disrepair 1
rotted window frames,faulty electircs,lack of ------- (can't read this word!) space in kitchen-works ongoing to solve these problems. kitchen 1
safety hazard on stairs - balustrade/spindles removed unfitness mitigated possibly by virtue of 1 adult (young) occupant 1
see attached 1
see attached note 1
see clip note 1
see memo 2
see note 6
see note. 1
serious condensation in bathroom not quite bad enough to make unfit. Ventilation is bad with sealed openings. 1
serious condensation problem with extensive mould growths condensation aggravated by tennants lifestyle 1
several items in disrepair basket, but house is warm dry well heated and ventillated all amenties and the defects are at the moment probably not having any significant effect on occupiers health. see note 1
slow running drains are defective - rest are minor repairs 1
some evidence on external assessment of failure of front wall ties but no access to first floor to check if affecting stability of first floor,ceilings in ground floor are cracked 1
some ingress of water to bathroom - could be considered unfit but easily remedied - replace slipped tile. 1
structure movement corner of rear wall and passage wall.Appears to be ongoing with displacement of brick course appearing likely to lead to instability problem medium term.Bordering unfit. 1
subjective decision substandard. amount of repair to large 1
tenant awaiting new bath,whb and kitchen in next 2 weeks 1
th e building has rising damp problems across the ground floor,the worst of this problem is located in th kitchen with a small amount in the living room. also penetrating damp noted in the bathroom. if the damp issue were worse in the living areas 1
the flat has a good modern kitchen, two shower rooms and plenty of space, good heationg so that the effect of the disrepair is not as much of a threat to occupier as it might be in a smaller unheated flat 1
the opening lights of the living room amd kitchen have been removed following a burglary. There are no gas appliances in property, no evidence of condensation. Repair not easily achieved as in nailed up windows 1
the property is a one bedroom house and the size of the kitchen reflects this. there is a single occupant who has moved the cooker to a dangerous position. questionable with it is unreasonable for occupation in this condition 1
there are a number of repairs required at this property,particularly to the windows & electrics.sections of the wiring are original & need replacing but the heavily used areas such as the kitchen have been rewired.-feel borderline unfit on disrepair 1
there is difficulty maintaining a reasonable standard of heating because of heat loss throughfabric disrepair,particuary because of ill fitting & defective windows.main source of heating is by ind. portable electric heaters.much internal fabric disre 1
this module is in my opinion unsafe with regard to fire safety. however it would have been converted with building reg approval to reach the standards at the time. 1
two double glazed upvc windows to kitchen no opening casements completly sealed units so no natural ventilation to kitchen inadequate appliance ventilation.however external door would provide some form of ventilation 1
unfit- grounds of damp arising from condensation/mould grown;may be impacted on more by lifestyle i.e.overcrowding & ineffective use of heating than in a similar property 1
unknown 1
ventilation/window size too small for bathroom.Less than 1/10 of floor area 1
ventilation:VERY small kitchen with no opening windows(only a door) and fully enclosed by modern brick+upvc conservatory-fan expels into conservatory+cooking areas.rest of the house ok,so unfit harsh. 1
vertical cracks in communal area on inner leaf of wall more pronounced on 2nd floor(5mm) 1
very little wrong internally,external repair items are generally small but cumulatively could add up to serious disrepair (borderline decision) 1
very small areas of damp.1m2 in kitchen and simila in rear bedroom. no damp smell or mould growth. kitchen has enamel table that could be used as work surface space available for installation of work surface cooker should be re-sited. Disrepair to 1
w.h.b. is in ground floor bathroom,whereas w.c. is on first floor. however,due to the location of the w.h.b. there is a reasonable chance that it might be used for hand washing and not sink. 1
w/t present but of poor quality kitchen is useable but very dated and high level damp present 1
wash hand basin in premises, but only in ensuite bathroom, not in main family bathroom - bordeline unfit 1
wash hand basin is not in the bathroom/wc compartment but in the adjacent rear bedroom (bath used for hand washing) 1
whb is cracked but not leaking: cosiderable disrepair but overall not 'unfit' in my view. 1
windows in lounge, kitchen and bedroom air no not have sufficient opening light ventilation. but not a family house and there appears to be no problems created by this. 1
wiring appears dangerous ?cables old switches & no earth.Further investigation but some pvc & new sockets & recentish? boiler fitted 1
DisclaimerPlease note that these frequencies are not weighted.
LocationEnglish House Condition Survey, 2004