| Bowed roof |
|
1 |
| Chimney breast removed in GF living room.No support to ch.breast in loft. |
|
1 |
| Condensation in roof space surface mould on timbers. |
|
1 |
| Damp on back valley timber to chimney. |
|
1 |
| Decay/wood boring beetles to some roof timbers and deflection of some rafters. |
|
1 |
| Deflection. |
|
1 |
| END WALLS ARE BLOCK. |
|
1 |
| Faults but not structural - Poor sarking felt. |
|
1 |
| Flight holes in purlins - possible insect infestation. |
|
1 |
| Front purlin timber split across its whole lenght at various points.No sign of sagging.Rear purlin ok. |
|
1 |
| Gable walls rebuilt - slight deflection to rafter on rear elevation |
|
1 |
| Householder described missing tiles and leaking roof but unable to gain access. |
|
1 |
| Loft room formed without strengthening the floor. Some deflection in ceiling joists |
|
1 |
| Most of roof structure replaced -section original-may need replacing soon. |
|
1 |
| Not divided adequately from house next door |
|
1 |
| Not properly divided from next door |
|
1 |
| Purlin ends not built in to gable end wall and party wall.Requires "bear filling" to 4 No ends of Purlins. |
|
1 |
| Purlins very small - defected thro` length - need supports or stiffening. |
|
1 |
| Rear extension roof appear bowed may need strengthening and recovering |
|
1 |
| Rear purlin deflected and park cracked. |
|
1 |
| Roof frame sag.Ceiling joists sag. |
|
1 |
| Sagging purlins undersized for roof (slight Sag) |
|
1 |
| Sagging purlins/water ingress .Infestation. |
|
1 |
| Sagging roof frame slightly |
|
1 |
| Signs of excessive condensation on rafters. |
|
1 |
| Some roof sag-difficult to see properly.Access too far away. |
|
1 |
| Wood beetle infestation- See section 21 |
|
1 |
| Wood worm everywhere |
|
1 |
| a section of timber has been added at right angles to the front purlin in the centre-roof sag |
|
1 |
| absence of felt. evident of raining in |
|
1 |
| active wood beetle infestation |
|
1 |
| additional bracing required between gangrail platform to tanks to be rebuilt and restrain straps fitted |
|
1 |
| additional bracing required between trussed rafters |
|
1 |
| additional bracing required to tresses as platform to cold where tank rebuild |
|
1 |
| additional support to portion? |
|
1 |
| clay tiles @ end of home-hh surveyed and to replace-prob battern + felt |
|
1 |
| condesation forming on felt space between sotfit and fascia possibly blocked by insulation- vents exist |
|
1 |
| cracked purlins |
|
1 |
| damp & woodworm |
|
1 |
| daylight around chimney stack, although roof felted |
|
1 |
| daylight see through slates |
|
1 |
| daylight visible in several places |
|
1 |
| deflection of 200f timber r. |
|
1 |
| differential movement - needs strapping. |
|
1 |
| dk |
|
1 |
| evidence of condensation on rafters but not a cause of immediate concern |
|
1 |
| evidence of previous fire damage to approx 50% of roof timbers.New timbers had been installed adjacent to fire damaged timber. No sign of sagging to roof structure-no action needed |
|
1 |
| extension-roof structure had not been adequately tied into original house causing movement&cracking to ceiling&walls of extension-problem resolved by tie bars now leaving erdecoration&repair to internal rooms of extension only |
|
1 |
| felt needs reprofing. roof is steel frame |
|
1 |
| front purlin thinned at end to chimney stack no fire wall to neighbouring property |
|
1 |
| front roof sagging. slipped slates missing felt |
|
1 |
| fully seperated from adjacent property. Undersized roof joints sagging with inadequate bracing? |
|
1 |
| high level purlin removed on front and back roof plane subsequently roof sagging |
|
1 |
| hip boards sagging |
|
1 |
| holes in and betweeen slates |
|
1 |
| humping loose tiles |
|
1 |
| leak where tiles off leaving water staining of principal possible rot |
|
1 |
| leaks |
|
1 |
| leeks around chimney causing serious degredation of brickwork and rot to roof purlins |
|
1 |
| major problems-roof stripped |
|
1 |
| many tiles off. some roof ? need refixing damaged by vandals |
|
1 |
| minor cracking to rhs chimney breast/party wall |
|
1 |
| minor dipping to rear roof. |
|
1 |
| needs roof strengthening re roof spread and ww noted |
|
1 |
| no access to loft |
|
1 |
| no sarking felt-open sky at joints all over. |
|
1 |
| no separation wall between dwellings in the roof. |
|
1 |
| no structural problems, but no underfelt and some replacement slates noted. |
|
1 |
| nominal woodworm attack |
|
1 |
| not answered by surveyor |
|
1 |
| number of minor leaks into timber |
|
1 |
| old repaired new strutsc |
|
1 |
| old roof already repaired though |
|
1 |
| old velux glass panels energy-in-efficient |
|
1 |
| open area to front mono pitch ridge & around svp.not structural-needs close inspection |
|
1 |
| peruns to rear insecure on brick piers |
|
1 |
| poor strengthenly - concrete tiles 'ong' slate |
|
1 |
| possible flashing missing around stack-checked ext seems ok |
|
1 |
| possible slight sag |
|
1 |
| prulin cut to form dormer no support to beam ends |
|
1 |
| purlin bowing |
|
1 |
| purlin(rafers)has been partly sawn through at mid point.This is leading to roof sagging (mentioned it to owner) |
|
1 |
| purlins sagging need strengthening |
|
1 |
| rafters deflected on front and rear slopes |
|
1 |
| roof humping |
|
1 |
| roof sagging |
|
3 |
| roof sagging, tiles slipped, felt torn |
|
1 |
| roof saging |
|
1 |
| roof spread |
|
1 |
| roof structure not enclosed. woodworm. inadequate repairs, no fire walls between dwellings |
|
1 |
| roof timber (hip) split along top 1/3 of its length |
|
1 |
| roof timbers sagging badly |
|
1 |
| rotten purlinn end to gable |
|
1 |
| sagging |
|
1 |
| sagging - seen from outside |
|
1 |
| sagging of main roof ridge |
|
1 |
| sagging roof in various places insuff/inadeq spacings at trusses |
|
1 |
| sagging spreading and common furniture beetle |
|
1 |
| seen externally - roof sagging |
|
1 |
| significate deflection in some rafters and front and rear slope ? |
|
1 |
| slight dip in main house roof |
|
1 |
| slight dip to lower rear roof elevation possible rott. |
|
1 |
| slip tiles on front roof |
|
1 |
| some de? from concrete roof tiles |
|
1 |
| some minor deffection of th rafter/tresses the front right hand side gable |
|
1 |
| some torn felt |
|
1 |
| somew add bracing desirable |
|
1 |
| split timber to ? parlin |
|
1 |
| st?????? |
|
1 |
| structural steelwork already installed in roofspace to strengthen front to back. |
|
1 |
| struts to main roof,already added. |
|
1 |
| suplphate damage to RHS chimney, movement to RHS party wall - not seen |
|
1 |
| suspect some overloading of beams from stone roof covering. Allow for strenghening |
|
1 |
| thickness of purlin reduced to 1/3 thickness |
|
1 |
| tile to hip overhang and course vain to miss gutter-cause minor damp to front bed |
|
1 |
| torn felt/ slight sagging |
|
1 |
| traditional roof purlins look under sized |
|
1 |
| undersized purling-sagging |
|
1 |
| w.c.ceiling to bathroom/wc has been dropped to 2.2m,the wc is set on a step reducing headroom to2.0m together with step makes wc defective.Difficult view through loft hatch but whole 1st floor ceiling has been reduced to 2.2m possibly to hide cottage |
|
1 |
| w/w old |
|
1 |
| w/w treated |
|
1 |
| water in slater? roof |
|
1 |
| weak timbers/gaps between slates nail sick |
|
1 |
| wet rot on rafters(2)adjacent to svp-(flashing+2/3 tiles need replacing) |
|
1 |
| wood beatle infestation |
|
1 |
| woodworm in timbers |
|
1 |
| woodworm infested and ratting roof timbres.Some defective brickwork to gabkes but only minor |
|
1 |
| woodworm to some timbers, slight movement to timbers. |
|