Bowed roof |
|
1 |
Chimney breast removed in GF living room.No support to ch.breast in loft. |
|
1 |
Condensation in roof space surface mould on timbers. |
|
1 |
Damp on back valley timber to chimney. |
|
1 |
Decay/wood boring beetles to some roof timbers and deflection of some rafters. |
|
1 |
Deflection. |
|
1 |
END WALLS ARE BLOCK. |
|
1 |
Faults but not structural - Poor sarking felt. |
|
1 |
Flight holes in purlins - possible insect infestation. |
|
1 |
Front purlin timber split across its whole lenght at various points.No sign of sagging.Rear purlin ok. |
|
1 |
Gable walls rebuilt - slight deflection to rafter on rear elevation |
|
1 |
Householder described missing tiles and leaking roof but unable to gain access. |
|
1 |
Loft room formed without strengthening the floor. Some deflection in ceiling joists |
|
1 |
Most of roof structure replaced -section original-may need replacing soon. |
|
1 |
Not divided adequately from house next door |
|
1 |
Not properly divided from next door |
|
1 |
Purlin ends not built in to gable end wall and party wall.Requires "bear filling" to 4 No ends of Purlins. |
|
1 |
Purlins very small - defected thro` length - need supports or stiffening. |
|
1 |
Rear extension roof appear bowed may need strengthening and recovering |
|
1 |
Rear purlin deflected and park cracked. |
|
1 |
Roof frame sag.Ceiling joists sag. |
|
1 |
Sagging purlins undersized for roof (slight Sag) |
|
1 |
Sagging purlins/water ingress .Infestation. |
|
1 |
Sagging roof frame slightly |
|
1 |
Signs of excessive condensation on rafters. |
|
1 |
Some roof sag-difficult to see properly.Access too far away. |
|
1 |
Wood beetle infestation- See section 21 |
|
1 |
Wood worm everywhere |
|
1 |
a section of timber has been added at right angles to the front purlin in the centre-roof sag |
|
1 |
absence of felt. evident of raining in |
|
1 |
active wood beetle infestation |
|
1 |
additional bracing required between gangrail platform to tanks to be rebuilt and restrain straps fitted |
|
1 |
additional bracing required between trussed rafters |
|
1 |
additional bracing required to tresses as platform to cold where tank rebuild |
|
1 |
additional support to portion? |
|
1 |
clay tiles @ end of home-hh surveyed and to replace-prob battern + felt |
|
1 |
condesation forming on felt space between sotfit and fascia possibly blocked by insulation- vents exist |
|
1 |
cracked purlins |
|
1 |
damp & woodworm |
|
1 |
daylight around chimney stack, although roof felted |
|
1 |
daylight see through slates |
|
1 |
daylight visible in several places |
|
1 |
deflection of 200f timber r. |
|
1 |
differential movement - needs strapping. |
|
1 |
dk |
|
1 |
evidence of condensation on rafters but not a cause of immediate concern |
|
1 |
evidence of previous fire damage to approx 50% of roof timbers.New timbers had been installed adjacent to fire damaged timber. No sign of sagging to roof structure-no action needed |
|
1 |
extension-roof structure had not been adequately tied into original house causing movement&cracking to ceiling&walls of extension-problem resolved by tie bars now leaving erdecoration&repair to internal rooms of extension only |
|
1 |
felt needs reprofing. roof is steel frame |
|
1 |
front purlin thinned at end to chimney stack no fire wall to neighbouring property |
|
1 |
front roof sagging. slipped slates missing felt |
|
1 |
fully seperated from adjacent property. Undersized roof joints sagging with inadequate bracing? |
|
1 |
high level purlin removed on front and back roof plane subsequently roof sagging |
|
1 |
hip boards sagging |
|
1 |
holes in and betweeen slates |
|
1 |
humping loose tiles |
|
1 |
leak where tiles off leaving water staining of principal possible rot |
|
1 |
leaks |
|
1 |
leeks around chimney causing serious degredation of brickwork and rot to roof purlins |
|
1 |
major problems-roof stripped |
|
1 |
many tiles off. some roof ? need refixing damaged by vandals |
|
1 |
minor cracking to rhs chimney breast/party wall |
|
1 |
minor dipping to rear roof. |
|
1 |
needs roof strengthening re roof spread and ww noted |
|
1 |
no access to loft |
|
1 |
no sarking felt-open sky at joints all over. |
|
1 |
no separation wall between dwellings in the roof. |
|
1 |
no structural problems, but no underfelt and some replacement slates noted. |
|
1 |
nominal woodworm attack |
|
1 |
not answered by surveyor |
|
1 |
number of minor leaks into timber |
|
1 |
old repaired new strutsc |
|
1 |
old roof already repaired though |
|
1 |
old velux glass panels energy-in-efficient |
|
1 |
open area to front mono pitch ridge & around svp.not structural-needs close inspection |
|
1 |
peruns to rear insecure on brick piers |
|
1 |
poor strengthenly - concrete tiles 'ong' slate |
|
1 |
possible flashing missing around stack-checked ext seems ok |
|
1 |
possible slight sag |
|
1 |
prulin cut to form dormer no support to beam ends |
|
1 |
purlin bowing |
|
1 |
purlin(rafers)has been partly sawn through at mid point.This is leading to roof sagging (mentioned it to owner) |
|
1 |
purlins sagging need strengthening |
|
1 |
rafters deflected on front and rear slopes |
|
1 |
roof humping |
|
1 |
roof sagging |
|
3 |
roof sagging, tiles slipped, felt torn |
|
1 |
roof saging |
|
1 |
roof spread |
|
1 |
roof structure not enclosed. woodworm. inadequate repairs, no fire walls between dwellings |
|
1 |
roof timber (hip) split along top 1/3 of its length |
|
1 |
roof timbers sagging badly |
|
1 |
rotten purlinn end to gable |
|
1 |
sagging |
|
1 |
sagging - seen from outside |
|
1 |
sagging of main roof ridge |
|
1 |
sagging roof in various places insuff/inadeq spacings at trusses |
|
1 |
sagging spreading and common furniture beetle |
|
1 |
seen externally - roof sagging |
|
1 |
significate deflection in some rafters and front and rear slope ? |
|
1 |
slight dip in main house roof |
|
1 |
slight dip to lower rear roof elevation possible rott. |
|
1 |
slip tiles on front roof |
|
1 |
some de? from concrete roof tiles |
|
1 |
some minor deffection of th rafter/tresses the front right hand side gable |
|
1 |
some torn felt |
|
1 |
somew add bracing desirable |
|
1 |
split timber to ? parlin |
|
1 |
st?????? |
|
1 |
structural steelwork already installed in roofspace to strengthen front to back. |
|
1 |
struts to main roof,already added. |
|
1 |
suplphate damage to RHS chimney, movement to RHS party wall - not seen |
|
1 |
suspect some overloading of beams from stone roof covering. Allow for strenghening |
|
1 |
thickness of purlin reduced to 1/3 thickness |
|
1 |
tile to hip overhang and course vain to miss gutter-cause minor damp to front bed |
|
1 |
torn felt/ slight sagging |
|
1 |
traditional roof purlins look under sized |
|
1 |
undersized purling-sagging |
|
1 |
w.c.ceiling to bathroom/wc has been dropped to 2.2m,the wc is set on a step reducing headroom to2.0m together with step makes wc defective.Difficult view through loft hatch but whole 1st floor ceiling has been reduced to 2.2m possibly to hide cottage |
|
1 |
w/w old |
|
1 |
w/w treated |
|
1 |
water in slater? roof |
|
1 |
weak timbers/gaps between slates nail sick |
|
1 |
wet rot on rafters(2)adjacent to svp-(flashing+2/3 tiles need replacing) |
|
1 |
wood beatle infestation |
|
1 |
woodworm in timbers |
|
1 |
woodworm infested and ratting roof timbres.Some defective brickwork to gabkes but only minor |
|
1 |
woodworm to some timbers, slight movement to timbers. |
|
1 |