(Possible) - strengthening/ replacement of some roof timbers required. Possible timber treatment. |
|
1 |
1 |
|
3 |
1 cracked rafter |
|
1 |
1 slipped slate on party wall |
|
1 |
1. deflection noted in main roof rafters 25% of wall plates starting to rotate. 2. Spiking required where rafters overseiling purlins collars require re spiking |
|
1 |
1rafter severeley notched but acceptable |
|
1 |
2 |
|
8 |
2 cracked rafters, 1 cracked purlin. |
|
1 |
3/150mm holes through party wall damaging fire integrity |
|
1 |
9999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999999 |
|
82 |
? felt cut away to a small area allowing birds to enter roof space |
|
1 |
Active Beetle infestation |
|
1 |
Additional bracing between the gang nail tresses. |
|
1 |
Brick party walls incomplete - 2 x 1.0m holes |
|
1 |
Brick pillar - supporting jointed durlin - cracked + slightly displaced |
|
1 |
Ceiling and voids adjacent to floors |
|
1 |
Ceilings hogging. |
|
1 |
Check to be made roof structure is properly supported. |
|
1 |
Did have roof spread - roof braced internally. |
|
1 |
Dislodged slate where chimney stack removed. |
|
1 |
Don't know |
|
1 |
ESTRA TIMBERS ADDED TO STRENGTHEN - BUT NON'T APPEAR TO HAVE BEEN EFFECTIVE |
|
1 |
Felt obviously wet in several areas. Evidence that water penetrating tiles. Also evidence of damp to first floor ceilings. |
|
1 |
Front and rear purlins dropped at hip ridge joint cause of slight roof sagging. |
|
1 |
Gangnail trusses with no cross bracing,water tank has no bearers to spread load to trusses. |
|
1 |
Gaps between ridge board (new) and rafters. Rafters appear to be secured to ridge with nails. |
|
1 |
HOLES IN ROOF/TORCHING MISSING |
|
1 |
Hip rafters spreading at ridge. |
|
1 |
Hipped end is sagging in the middle slightly. Probably requires additional members . |
|
1 |
Historic damp staining to timbers but no remedial repairs or treatments necessary |
|
1 |
Hole in Roof |
|
1 |
Hole in roof coming next to chimneyey (only 6" diameter approx. - plugged with plastic sheeting!!!) |
|
1 |
Inactive w/w in timbers which are undersized but do not require strengthening. |
|
1 |
LACK OF BRACING TO TRUSSED RAFTERS |
|
1 |
LONGITUDINAL AND DIAGONAL BRACING MISSING |
|
1 |
Lack of bracing |
|
1 |
Left blank |
|
1 |
Longitudinal and diagonal bracing required between the gangway truss rafters. |
|
1 |
Loose roof tiles and no roofing felt. |
|
1 |
MINOR DRY ROT AND EVIDENCE OF WOODWORM |
|
1 |
Minor cacking to roof purlins - monitor |
|
1 |
Minor slippage of tiles. |
|
1 |
NONE ENTERED |
|
1 |
New being put on,with new felt,using existing tiles double roman |
|
1 |
New roof tiles - near completion |
|
1 |
No fire walls between dwellings in loft space |
|
1 |
No insulation to partition walls between bedrooms and roof void - so halve (average) 150mm thick to 75mm? |
|
1 |
No internal loft access. Roof is very old. Deduce no insulation. |
|
1 |
No propping to purlins at mid span. |
|
1 |
Not structural daylight visable. |
|
1 |
ONE MISSING SLATE |
|
1 |
Old timbers have been partly replaced when roof cover replaced. |
|
1 |
Possibly active wood-borer in roof timbers. |
|
1 |
Problems with floor joints for room |
|
1 |
Purlin delocation, stress cracking, water penetration |
|
1 |
Purlin needs proping. |
|
1 |
Purlins in main roof laid at 90 degrees to rafters and have 'BOWED' and are split in main section. |
|
1 |
Rafters to outrigger do not appear to be secured at ridge, simply resting on wall/slate pads. |
|
1 |
Rafters undersized. Install purlins & struts. |
|
1 |
Re- felting needed in places |
|
1 |
Reinforcement has been introduced + tie measures, no signs externally of roof spread or sagging. |
|
1 |
Roof frame strecher required. |
|
1 |
Roof half felted (20 years ago) |
|
1 |
Roof has started to started to spread & mild steel restraint straps have been fitted to purlins & rafters |
|
1 |
Roof sagging - needs strengthening |
|
1 |
Roof sagging but not progressive |
|
1 |
Roof was moving and galvanised straps and ties have been inserted to stiffen roof |
|
1 |
SLIGHT SAG NO ACTION REQUIRED |
|
1 |
SLIGHT SAGGING |
|
1 |
SLIGHT SAGGING - NEEDS SOME STRENGTHENING WORK TO STRUCTURE |
|
1 |
STRUT BROKEN TO ONE PURLIN. TEMPORARY REPAIR. |
|
1 |
Sagging of hip ridge timbers & purlin support. |
|
1 |
Sags to front porcin and ceiling hoists, slight bulge to front corbelling |
|
1 |
See note. |
|
1 |
Serious vandalism & fire damage will require 10% roof structure repair/replacement. |
|
1 |
Signs of damp to ridge timbers ar party wall |
|
1 |
Slight bulging of purlin bar - not visible externally. |
|
1 |
Slight roof sagging |
|
1 |
Slight sagging of roof plains |
|
1 |
Slight sagging to rear lh slope visible from outside, no internal inspection possible. |
|
1 |
Slight sagging towards valleys |
|
1 |
Slight sagging. |
|
1 |
Slight tile erosion to nibs of tiles.Light coming around rear of stack no dampness. |
|
1 |
Some defection of rafters and parlin but likely to be historic. Roof appears to be stable as do walls on which roof structure bearing. |
|
1 |
Some historic damp staining to timbers, but no remedial treatments required |
|
1 |
Some strengthenong required to structure to supply concrete tile covering |
|
1 |
Some support timber removed to form a DIY loft conversion. Does not comply. |
|
1 |
Structural problems, but remedial action has been taken already - defective purlin. |
|
1 |
Strutting to roof trusses inadequate. |
|
1 |
TIMBER INFESTATION |
|
1 |
UNDERSIZED PURLINS |
|
1 |
UNDERSPRAYED WITH FOAM BETWEEN FACIAS DIRECTLY ONTO TILES - QUESTIONABLE VENTILTION TO ROOF TIMBERS |
|
1 |
Wet rot but now been treated. |
|
1 |
Wood borer infestation |
|
1 |
Wood worm |
|
1 |
Woodworm - but structure appears ok - and reinforced to account for concrete tiles. |
|
1 |
additional bracing req'd between the gargnall roof trusses |
|
1 |
additional bracing required |
|
1 |
additional bracing required between gangrail truss rafter |
|
1 |
additional bracing required between the gangral trusses. |
|
1 |
additional longitodinal and diagonal bracing required |
|
1 |
air gaps, underlay felt missing. |
|
1 |
back addition roof purlin poorly strutted and proped at intermediate position- noexcessive deflection |
|
1 |
badly torn roofing felt, broken batons |
|
1 |
bowed and broken vertical 'timber hangers' in roof space compressed |
|
1 |
ceiling joints sagging - roof timbers small |
|
1 |
cement fillet under slates falling off into roof space |
|
1 |
charring to roof timbers from fire in house prior to tenancy. |
|
1 |
collars removed though no movement over 25 years renew collars 2 no. |
|
1 |
collars slightly bowed,some tears to felt and signs of leaks to front slope |
|
1 |
damamged support member/ minor.spray foam on underside of roof cover? proprietary system not diy |
|
1 |
defective tiling, no felt, some rotten rafters |
|
1 |
deflection in rafters visible as externally as humping but historic in nature |
|
1 |
dip to ridge |
|
1 |
displaced tile |
|
1 |
distortion on gangrail trusses has resulted in the execution of a comprehensive bracing to the roof - no further work is required. |
|
1 |
don't know |
|
1 |
dry rot in top floor ceiling joists tied to rafters - but no damage to rafters as far as can be ascertained |
|
1 |
ducting to vent from bathroom not connected |
|
1 |
ends of purlius loose where built into party walls |
|
1 |
evidence of rain penetration |
|
1 |
excessive deflection on roof ridge beam.excess deflect in purlins?rotated purlin struts,wall plate overturning. |
|
1 |
fire damage to all original timbers,secondary timbers installed alongside original roof timbers.as such no action necessary in section 21. |
|
1 |
found woodworm attack in roof structure |
|
1 |
from outside - roof sagging at ridge |
|
1 |
front lower purlin twisting where built into brickwork |
|
1 |
fungal attack to a rafter |
|
1 |
furlin bowing, needs additional strutting |
|
1 |
gable end wall bowed inwards |
|
1 |
gang nail roof trusses - no bracing of roof |
|
1 |
holes in felt |
|
1 |
inadequate supports no end bearings |
|
1 |
inadequate trada bracing - no nodal to some parts and no bracing to u/side of rafter chards |
|
1 |
joint in portion to new roof slope has openened up and needs to be plated |
|
1 |
lack of bracing |
|
1 |
lead valley split & roof timbers show signs of water penetration to rear elevation. |
|
1 |
leaking back gutter to chimney - flashing problem |
|
1 |
leaking valley - some wet rot underneath evident |
|
1 |
loft conversion with no permenant stairs. |
|
1 |
loft hatch nailed up . council have upgraded insulation within last 6 weeks |
|
1 |
loose tiles |
|
1 |
metal bars bracing roof front to back |
|
1 |
metal fixing of trussed roof section not adequately tied in to party wall |
|
1 |
minor sagging? |
|
1 |
minor sarking felt detachement < 10% to minor to impact on fitness assessment. |
|
1 |
minor splits and twist to rear purlin |
|
1 |
minor tile displacement (1 no) and droop in cauking felt. Too small to have any effect on fitness. |
|
1 |
minor wind driven rain gets into stone flag roof or fine snow-rear slope only front re roofed not structural problem & longstanding & not health threat/unfit |
|
1 |
minro woodworm attic probably dormant in loft |
|
1 |
misplaced and broken tile battons. no sarking) |
|
1 |
mould showing signs of roof leaking and deck failure - nothing showing on ceiling - recently decorated |
|
1 |
movement signs, possibly due to chimney removal |
|
1 |
movement to ceiling joints and hips daylight visible |
|
1 |
nil collars. struts/hangers rear purlins jointed and supproted by insubstantial hanger(green log) |
|
1 |
no bracing to trusses |
|
1 |
no broving to gangnail trusses |
|
1 |
no collars/insufficient struts,concrete replacement tiles,some bowing |
|
1 |
no description |
|
1 |
no description given |
|
1 |
no diagonal bracing to truss rafters |
|
1 |
no diagonal bracing to trusses |
|
1 |
no diagonal cross bracing to trussed rafter roof |
|
1 |
no foof felt; but no leaks |
|
1 |
no inosection possible |
|
1 |
no sacking felt |
|
1 |
no struts to back |
|
1 |
no wind bracing to trusses trussed roof |
|
1 |
not much diagonal bracing to trusses |
|
1 |
note: ceiling joists - worn - assume historic - & new roof structure (front roof only). |
|
1 |
old w/w-leaking roof covering-junction with next door-flashing detail poor |
|
1 |
one of three main purlins split along most of its length |
|
1 |
only half bungalow has roof void |
|
1 |
original roof covering-bodging mostly dropped-inadequate purling-expect nail sick |
|
1 |
over stressed purling |
|
1 |
party wall defective adjacent to purlin seatings. also not a full fire break to adjoining property |
|
1 |
plasterboard |
|
1 |
platform for cold water tank not properly constructed |
|
1 |
prevoius woodworm infestation treated.But some evidence of recent frass on one part. |
|
1 |
promenent sags and purlins? have been peeled,some minor rot,some adaption to structural members |
|
1 |
purlin failure not visible externally - requires strapping |
|
1 |
purlon sag - front only visible no access to rear roof space |
|
1 |
rafter joints at ridge board suspect. Appear that exta timber rafters have been installed |
|
1 |
rafters and purlins bowed, with some splitting of timber to main roof |
|
1 |
rafters deemed structurally unsound |
|
1 |
rafters not adequately secured to ridge board |
|
1 |
rain clearly penetrating roof but no evidence in flat |
|
1 |
reinforced to prevent roof spread and sagging added timbers and secured joints |
|
1 |
roof appears to be slightly sagging & in need of additional support. |
|
1 |
roof extensively strengthened, large hole to felt at front and birds nest present |
|
1 |
roof previously sagged but has been strengthened |
|
1 |
roof requires strenghtening |
|
1 |
roof sagging |
|
2 |
roof sagging not serious |
|
1 |
roof sagging/uneven ceiling |
|
1 |
roof slate slippage/party wall not built up torafters -no fire stopping (average 350mm gap) |
|
1 |
roof timbering extremely old. some sagging and likely to be progressive |
|
1 |
roof timbers are very slender-no foreseen problems.no roofing felt -daylight thro' a few tiles |
|
1 |
roof timbers sagging |
|
1 |
roof very low pitch 1/2m. rise at ridge and strenghtened ridge rafter joint using plywood plates. |
|
1 |
rotten joists |
|
1 |
sacking felt torn |
|
1 |
sagged rafter/ties removed |
|
1 |
sagged rafters |
|
1 |
sagging |
|
1 |
sagging along main purlin |
|
1 |
sagging at valley due to unsupported purlins |
|
1 |
sagging main roof timers |
|
1 |
sagging of hip rafter causing roof sagging |
|
1 |
sagging of main roof structure-inadequate struts/collars |
|
1 |
sagging on front pitch round dormer |
|
1 |
sagging purlins |
|
1 |
sagging roof timbers loose tiles |
|
1 |
sagging seen externally reflected inside - strengthen woodworm to purloin |
|
1 |
sagging timbers mainly unfelted roof |
|
1 |
sarking felt decaying |
|
1 |
several areas of torn feet/no evidence of dampnesss in bedrooms |
|
1 |
severe condensation |
|
1 |
severe woodworm to all timbers |
|
1 |
signs of dry rot starting in main rafters |
|
1 |
slate missing |
|
1 |
slight corrosion to steel frame roof structure |
|
1 |
slight deflection on purlins |
|
1 |
slight sag evident from outside |
|
1 |
slight sag, front & rear |
|
1 |
slight sagging but due to age no work required |
|
1 |
slight sagging on rear |
|
1 |
slight sagging to rear slope,purlin dropped |
|
1 |
slight tairs to felt on rear elevation |
|
1 |
slightholed slate water damage to valley board |
|
1 |
slipped tyres |
|
1 |
some daylight visible from slipped slates. all torching fallen off. |
|
1 |
some daylight visible + slipped slates |
|
1 |
some distortion to secondary rafters over 1st floor bay. spray foam to underside of tiles |
|
1 |
some felt deterirated - needs reroofing |
|
1 |
some pulins not built in adequately lack of ventilation to roofspace and signs of slight condensation damage. |
|
1 |
some sagging of rafters especially to rear addition |
|
1 |
some slight gaps to slates, no torching |
|
1 |
some slipped slates to rear extension |
|
1 |
some woodworm noted probably not active - no signs of frase or beetles |
|
1 |
split purlin clamped for reinforcment - appears adequate |
|
1 |
strengthen |
|
1 |
strengthening required |
|
1 |
strengthening required due to sag |
|
1 |
strengthening timbers in place to prevent further spreading of roof |
|
1 |
strut unattached from purlin |
|
1 |
supporting beams are splitting and may need replacing |
|
1 |
suspect |
|
1 |
tears to roofing felt around area of mould growth on rear bedroom |
|
1 |
the beam bowed due to weight of roof + too small members |
|
1 |
timber infestation |
|
2 |
torching falling off underside of tiles daylight visible |
|
1 |
torn felt in two places |
|
1 |
torn felt/mould growth |
|
1 |
treat woodworm |
|
1 |
truss rafters-diagonal bracing absent. no evidence structural distress however |
|
1 |
turn roofing felt hoacd to tamber |
|
1 |
two holes in slates - no sarking? |
|
1 |
underside of rafters boarded. tile vents on outside not ventilating whole of structure |
|
1 |
undersized roof members especially purlins addition support added if reroofed structure needs replacing. |
|
1 |
undersized timber - slight sagging |
|
1 |
undersized traditional purloins and undersized ceiling joists and mouse droppings not ( bats). |
|
1 |
unknown |
|
2 |
unusually lightweight frame with only single purlin either side of main pitch. |
|
1 |
vertical cracks to supporting wall, probably long standing in view of age of property |
|
1 |
very small trapdoor-ladder unavailable as no parking nearby-occupant says he insulated many years ago |
|
1 |
w/w |
|
1 |
w/w cour asbestos sheet roof |
|
1 |
weight of clay tiles has distorted old timbers |
|
1 |
wood boring beatle and major sagging/uneveness. |
|
1 |
wood boring beetle infestation |
|
1 |
wood worm, owner says it has been treated |
|
1 |
wood-borer infestation to main roof timbers.Appears still live.some treatment undertaken |
|
1 |
woodworm |
|
1 |
woodworm attack to root timbers is still active |
|
1 |
woodworm minor |
|
1 |
worm - suspect historic - no fras |
|
1 |